hayward blue essence troubleshooting hayward blue essence troubleshooting

It is plugged into a gfi outlet. I am getting air bubbles coming from my return jets in my pool. Thanks Davy for your quick reply. I believe you must have some type of switch, for code cant just wire it directly to the breaker. I cannot locate the model # on either but believe the filter is a c250. Sometimes it is just a stick or debris stuck between the valve diverter (aka rotor or footpad) and the spider gasket, and a little wiggle or jiggle or repositioning of the handle can seal up the waste port, for a time If it reoccurs, this means that the spider gasket is twisted, worn or damaged. Checked circuit breakers inside and out and checked to make sure power is getting to pump. It could also be the wiring from breaker to timer, or timer to pump, or just breaker to pump, if there is no timer or other switch (and if there is no other switch, the breaker is likely just worn out from overuse). It could also be the centrifugal switch located in the rear of the motor, on the end of the shaft, check for looseness, broken spring or other damage. Its a good piece of troubleshooting. Automatic reset is immediate when the switch opens. The Aqua Rite runs at maximum out for for the remainder of the current pump cycle or for 24 hours, whichever comes first. You can also contact Hayward Technical Service for help directly at (908) 355-7995. },
Inspect the gasket as well, for nicks, dry-rot or other damage that may affect the seal. The HS (High Sense (water temperature) will appear if the water sensor is reading above 105 OR if the sensor detects an increase of more than 6 with-in 60 seconds. Went to clean the pool filter a few days later and now when turning on the pump it made a loud grinding noise. After removing the capicitor and the thermal load, we were able to get a 7/16 wrench on the shaft at around 12 oclock, but the shaft only has two flat sides and we are only able to move the shaft like 1/12th of a revolution clockwise and counter-clockwise (back and forth between 11 and 12 oclock). What am I doing wrong??? Check it out, it could start a fire! We are headquartered in Valley Stream, New York, just outside of New Theory and practice | Find, read and cite all the research you need on ResearchGate We would like to show you a description here but the site wont allow us. If I try to shut it off, nothing happens. The pump does not start. You should get it back same day or next day, in most cases. Hi George, that is a strange one, because you dont backwash, yet pressure returns to normal, just by shutting pump off for a minute, then restarting? Verify if your flow switch was installed correctly. hayward super pump C48L2N134B1. The air may be there on high speed too, its just not noticeable. 3. pipe going into pump Troubleshooting a Salt Chlorinator First, check power. Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. Hi David, impellers that have signs of wear are usually operating without a problem. Normally when the device is turned off and we do get the lid off, water runs back into the basket from the filter, it almost sounds like its creating almost a vapor lock, like in an engine. Flipped the breakers back on this morning after problem fixed. Now wont turn on when I plug back in and my circuit breakers are not popped. What is the incoming voltage on a H-150 pool/spa heater ? It got very wet and tripped the breaker. If not the skimmer being blocked, then its an air leak BEFORE the pump impeller. 25 LibriVox About. Put your power leads on both sides of the transformer, should be 115V IN, and 28V OUT, (or close to those numbers). Juat replaced motor. Improper voltage wiring is the usual culprit for smoking pump motors. Check that there is no additional valve to open on the backwash line, and if a flexible backwash hose is used, that it is rolled out. likely not a fan or impeller problem, because at 3500 RPM (or less), it would wear down anything broken in just a few minutes. "name": "In The Swim",
That is the black cylinder in the rear of the motor, located at 9 oclock. Took it to pool mart and they cleaned it out and said everything was fine inside it. Checked to make sure nothing was blocking it. 24V after the transformer is present. We purchased a Hayward D.E Filter last summer. 1.5 horse power. Im losing my mind. It overheated very badly, even burning the hayward sticker off the pump itself maybe a month ago. On the Swim Pro filters, check the two lock nuts under the lid, which secure the pressure gauge and air assembly, and be sure the filter is seated firmly into the base. With your timeclock or switch turned on, you should see about 220V, give or take 10%. Here is the manual: Now, it could also be rust inside the motor, natural when a pump sits for long periods of time, in a non-climate controlled location. The situation is either an air leak in FRONT of the pump, around the pump lid, the pipe coming into the pump, or leaky suction side valves. The pump is connected after the filter and before the salt chlorinator. Replaced battery on top of pump cover and still nothing??? Ive been told my Hayward Vsp has been shutting itself off for low power issues, even though no power issues are present. If they are tight, pull out the cartridge and drain the tank whatever it is may be laying in the bottom of the tank. Since that time the mechanical seal has failed four times each time within 2 months of operation. See if your test button has popped out on the outlet, or perhaps you have one on the breaker, a test/reset button. Motors that are reversible always ship from the factory at 230V, and need to be manually switched to accept 115V. hayward blue essence troubleshootingautodrive microfiber towels. Why would this suddenly happen? However after shutting it manually, the pump wouldnt start again. If one of the keypad buttons is closed (or pressed) for more than 30 s the error code will be displayed but the control will continue to function. I dont think it ran dry, if the pump outlet hose came loose (not the inlet?). Do you know what would cause this? Specialties: Cycling, Kickboxing, The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. Especially a drip from the clamp band or the threaded fitting on the outlet port of the pump, or a dripping shaft seal, or leaking housing. Hi Joe, Low Flow would be indicating that the water flow coming into the pump, heater or salt system is insufficient. You are also using the diffuser? If thats not the problem, then it could be that you replaced the motor with a full rated motor, but the impeller (and old motor) was an uprated motor, or vice-versa. Check the wiring of the pump cord, comparing to the wiring diagram printed on the motor, to be sure that they are connected properly, should be wired for 115V (not 230V). APPLY FILTER Pumps Filters Heaters Cleaners Sanitization Automation Lighting White Goods Accessories Solar Safety Do they sometimes have to be replaced? "name": "Davy Merino",
The breaker is probably overloaded. Thank you for your time, Jed. Inspect the area where the wires connect to the motor, aside from that Im stumped havent had the chance yet to work on too many VS motors. But you could look further at the wires on the back of the terminal board, following them to the capacitor and switches problem lies where the power dies! After 15-20 minutes, after cooling, the switch will close again, and the motor should restart. I bought a new pump thinking was something wrong with pump on off switch. The electrician also installed w new capacitors on the pump and still same problem. Is there something on the board I need to change? The o-ring should be a very tight fit also, not loose in the groove of the lid. Hi Tim, If Assy A has a bad motor (test it? Well, you first need to inspect it, and if the parts are broken, replace them. The impeller does not need to be spun on too tight, the spin direction of the shaft will keep it snug, so just hand tight. . This is common maintenance for any pool Troubleshooting Your Hayward Aqua Rite System, Copyright 2020 INYOpools All rights reserved. One of the tads were not in the slot. The click I was speaking of is definitely in the motor, not the outlet, although I realize they are right next to each other. Compare to Hayward T-Cell-15 Good news.not really. It ran and then we shut it off. Hi, it is either an air leak (a non-issue if installed below water level), or the suction pipes are too small for the pump size, or the hose may be collapsing inward under pressure. Hi Davy, I have a Hayward Super II which has been running well for years. For the pool winterization, the usual practice is to remove the filter and drain plugs, and then use rubber expansion plugs, or threaded plastic plugs, to close up the pool skimmer line and the pool wall return lines (where water returns to the pool), after the pipes are drained of water. I would recommend getting a plug-in timeclock so you dont need to plug/unplug it all the time. The centrifugal switch may be loose, or the stationary switch may be bent and not releasing. After trying every chemical under the sun and replacing the sand, I pulled the trigger and started from scratch. Cheers! Today two years later, same company opened pool,pump stuck and want to install another 3400vsp for $1330. It is a Hayward Super Pump 1.5 HP (model #SP2610X15). In some instances, it could just be a bad breaker. Hi Leah, when the pump is barely pumping, the problem is either in front of the pump or after the pump. The new one is doing the same thing. Hey John Hi Todd, that would be rare but not impossible sometimes bearings are not set perfectly, or manufactured perfectly, or the tolerances of the bearing housing could be off by a hair, from something being loose, or mis-shaped or if the motor were dropped from a height. Please note: The majority of our literature and brochures are in English only. It appeared that I couldve pulled them right off if I tried. Thank you "dateModified": "2/24/2015",
You need to use a K-1766 salt test kit or a calibrated meter. Hi Deb, SF (Sensor Failure) indicates that the temperature sensor (thermistor) is not getting good data to the circuit board. Hi Tim, smoke from the motor? Hi Shannon, well thats encouraging. Sometimes pump lids can also warp or even the pump housing or internals, in cases where the pump got REALLY hot, but that is rare, but if the cause, youd need some new parts, or new pump. Please let me know what can be done if anything we may be calling for info. Finally, could be that the voltage is not quite right, one of the legs (power wires) not providing enough power. So, when a pump is surging or pulsing, and not getting up to full head it is either starved for water, because of closed incoming valves, or too big of a pump for too small inlet pipes or because of air being pulled into the pump from air leaks or low water level in pool or from some obstruction in the lines, pipes or valves, a clog or something broken off I have found a Drain King useful in diagnosing such things, find at a hardware store, the 1.5-2 model, and connect to a garden hose, to pressurize pool systems and pipes, to look for leaks, or used as a water hammer to force clogs out, back the other way. Dec 14, 2021. But not likely, since its been there for years. Please advise. They can also fail if used on a salt pool (there are salt seals that can be used), or if the motor and shaft heats up to high temps. Fourth possibility is that the other lines (skimmer or main drain) are partially clogged or valves closed, not allowing enough water to enter pump, while vacuuming. High water flow (>125 gpm) into the heater. Hi Cindy, most likely an air leak. Air can enter pressure side if the water is not making it all the way to the top of the filter or chlorinator. So changed out the motor with a Century model. If you remove the motor from the pump, and then turn on the power very briefly if the noise continues, its the bearings, if it runs quiet (high speed), then look to vibration or cavitation. My question to you is what to do from here. SOme pumps have an open bracket where you can see the shaft, but not Hayward. Returns are getting good supply, the gauge on filter is bouncing up and down. What you want is the owners manual for the heater. The third thing to check would be an obstruction on the pressure side of the pump, clogged impeller, clogged filter, closed return side valves or plugs in the wall. If your hose has union connections that are tightened to connect to the filter, you may try some Teflon tape on the valve threads, or may need a new hose assembly, if the union threads are damaged. The early revisions dont work with the TCELL5 or TCELL9. *If your water temperature reads 215 degrees F, the cell temperature sensor is shorted and your cell needs replacing. The control is set for the wrong turbo cell type. The wire size may depend on the distance of wire run. Is this a new or older installation? The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. The motor may be dead, or possibly not. This just started. died and I put in the old repaired motor. Trying not to damage impeller. Now I turned the power off beacuse the circulation is not working and afraid the filter might blow up by the high pressure. We are headquartered in Valley Stream, New York, just outside of New Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. dr myers ultrasound. Hi there, I made the very unfortunate decision to rent my home to a friend. If not those, it could also be a short in the motor windings, which would be a major failure, requiring a new motor. It sounds more like a filter problem, one that might be fixed by using a good pool filter cleaner, or you may need new filter media. Hi again, I dont have a shaft seal replacement video, but there are many on youtube. dhp faux leather club chair; hanna salinity tester calibration; Now if its not an air leak, surging can also be caused by a clog in the pipe, usually a solid object like a golf ball, getting sucked back and forth in the pipe. First inspect wiring, to be sure everything is tight and secure, and there are no loose wires, or anything that looks wrong back there. Hi Joe, I would first suspect an air leak, Superpumps can also draw air from a loose drain plug and easily around the square lid gasket but the usual suspect is the pipe coming into the pump. Per your article, it sounds like I need a new capacitor. If lots of air churns when you shut the pump off, and the water quickly blasts out of the pump, thats likely a suction side air leak. An error was detected in the ignition control circuit board. I only rotated the one piece how can the screws not go right back in? Be sure though, that the motor has plenty of air flow, and the air flow vents are not blocked, and that incoming voltage is not too high or too low. You must log in or register to reply here. how to watch past broadcasts on twitch. "height": "219",
Good day everyone. Check if the pump will now run. This is a brand new pump out of the box that was installed and the inlet is drawing water in and filling basket and the outlet is discharging water but it just trips the breaker everytime. Hi Tiffany, in most inground pool cases, the pool pump should be powered by a breaker on the home main panel, which powers a breaker on the pool equipment pad sub-panel breaker box. Hi Kenny, not to my knowledge, you should see some display even without gas hookup. Old pump ran on 120v and ran just fine till we broke it. 3 No air bubbles on my returns when not vacuuming Hi Carolyn, When a pump displays those symptoms, its usually an air leak or a collapsed suction hose, or a very dirty filter. put in a new motor and had the old motor repaired. Mark, if you can hear the motor winding up and down, then it could be the cord. Although in low speed, chlorine is not generated so not sure why even run the low speed. Check the shaft for free spinning movement, and check the capacitor for signs of failure (bulges, cracks, smoke). Thanks! I have no pressure on my filter. It would run fine. Thanks. A lb of DE is by volume, equal to a 1 lb coffee can, or about 4 cups of dry measure. Shut off the valves or plug the skimmer and return, so you can keep the water in the pool while you get it sealed up. Any suggestions? Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Have a Hayward SuperPump. or if i let it rest for like 10 to 15 min it will start right up on its own when i hit the switch. Any advise on what is the problem? So, if you replaced the handle assembly and valve, aka the Key Assy, item SPX0714BA, and water is still coming out of the backwash line? Getting ready to start up my pool , flipped the breaker and nothing. Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. Also make sure that the impeller wear ring is correctly facing, and that the seal plate and mounting screw are aligned properly, and that the diffuser and diffuser o-ring are seating properly. It could also be that the power cord is not rated for 15 amps, which is the likely size of the breaker for the outlet (but check the breaker amp size). If you're researching Blue Essence, we're more than happy to help you figure out the best solution for replacing, upgrading, or repairing your system. Hi Stacey, the build-up of pressure usually means that the filter is clogged, as you likely know. We had this issue with our older Hayward pump near the end of its life, but it would throw the breaker every time we tried to start the pump near the end of the summer last year. You can only compare 4 products at a time. Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. Thanks. My pump seems to be working fine but Im having an issue with the flow pulsating out of the filter. If error still occurs, replace drive. So, check that the air vents on the motor are not clogged, and that the fan in the rear is not clogged, or doesnt have something wrapped around the fan, and also around the pump, check that air flow is not blocked by mulch, or by pump being installed in a small box, or anything that prevents free flow of cool, outside air. i have a 4 wire set up, ground, line , low speed,high , just want to make sure i wire correctly, 1- line 1, 2- high speed, 3or4 to low speed? Motor was only humming. This is a black cylinder located in the back of the motor, at 9 oclock, which acts as a battery to give the motor extra juice to start. On an Intermatic timer clock, there is a tab, at around 4 oclock on the dial, that is pushed to the left to turn off the timer, or override the timer settings. Click OK to extend your time for an additional 0 minutes. Glad that you replaced the sand, normally lasts 5-7 years on larger sand filters, but filters below 21 diameter need it more often, and very small filters 12-14, need it almost every season. http://bit.ly/InyoPoolsListen to the Poolside Chat podcast!iTunes:http://bit.ly/PoolsideChatSoundCloud:https://soundcloud.com/inyopools-comLIKE us on FACEBOOK! There was alot of debris once I removed the assemblies and some water below wiring. Hi Terri, when you connect the vacuum hose to the skimmer to start vacuuming, this is like increasing the length of the pipe from the pool to the pump, which makes the pump have to work harder, kind of like drinking through a very long straw. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. 14mm Magnetic Spark Plug Socket, Hi Mark, there are salt and ozone resistant shaft seals that can be used, the salt could be the problem, or it could be caused by a water-hammer effect, where flowing water is shut-ff suddenly by a closed valve on the return side, or turning a filter valve while the pump is running. Motors have a thermal overload switch to shut off the motor when it gets too hot. Next year, June 21, 2021, is the date that VS (Variable Speed) pumps will be required, over 1-hp in size. Hayward pumps use different shaft seals, you can find the correct one here: https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG . Thanks, Jim, Jim, they can be sticky sometimes. I also made sure that the board was changed from T9 to T3 cell. Could be a short in the wiring that could be tested with an Ohm meter, for resistance. When the valve is positioned on the filter, it should slide over the standpipe tube, or the center pipe that is connected to the laterals will slide up into the bottom of the valve, and the valve is pushed down to make a tight fit against the filter flange, and then the clamp is supposed to hold it tightly. Like it is locked up. If the wires are tight, I would suspect a bad capacitor, or wiring to or from the capacitor. '' ''' - -- --- ---- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. It should be the receiving 115V or 230V, depending on how it is wired, plus/minus 10%. Also possible that the rubber is damaged, inspect closely for signs of wear while cleaning it. Hello, I have a H200 natural gas heater . Is this normal or is there a malfunction? Could also be a vibration noise, or rocks/pebbles in the pump basket. Checked the circuit breaker and turned it off and on. "primaryImageOfPage": {
Our variable speed Hayward pump, when not running on highest speed, keeps resulting in FLO errors. Products, Learn About In such case, filter pressure is lower than normal, if the impeller is clogged. If you vacuumed the floc residue into the filter, you should be able to remove most of it with a thorough backwashing of 5 minutes or so. This is actually the second motor in 6 months. Please advise ). Remove the cover plate, and use an insulated screwdriver to discharge the capacitor. Now what? Hi Carolyn, yes either the thermostat or other temp sensor, if present, would be responsible for that symptom. I am a new pool owner and first Hayward pump. I have a maxi-flo 2 and it just stopped working. I have a Hayward pump that will backwash but nothing else. Diagrams, Pool Just opened up the pool and the Hayward Super Pump worked just fine until we started vacuuming the bottom. I opened the control panel during a rain storm (down pour) to turn off the filter. Hi Davy,I have a Hayward pump and its not priming.The basket is only filling up halfway with water. It could be dead. Select Product to Register: Step 4: Enter the registration information for your product . Could possibly be loose wires on the motor or timer, possibly a loose centrifugal switch or stationary switch on the motor, or maybe the windings in the motor are shorting out. I can see the water trickling in to the filter after a while, and the output becomes very limited. Does this seem odd or excessive? If all is good, there is a possibility that the breaker or GFCI outlet is bad. },
I had an old hayward 1.5 hp power flo matrix 2 speed pump. I had my hayward pump serviced because it was making a sweeping sounda overheatng and kept shutting of after an hour . Any insight would be helpful. 2. check the pump motor wiring, at the timeclock and the motor. It does this everyday and then starts working like normaly for the rest of the day. Stackable Rose Gold Wedding Bands, If recalibrating your salt level did not resolve your problem, then your cell or your PCBoard is bad and needs replacing. Grass clippings, seeds, gravel or other small debris can clog an impeller and reduce suction. when i reassemble after cleaning, pump works great for about 5 mins even at 30 psi. Excuse my ignorance, but what could be the problem? Increased flow this year may be from the new sand, and higher flow makes it easier for air leaks to appear. Air can also enter through split vac hoses, but since yours is new Third problem could be if the new pump moves much more water than the old pump (not all horsepower pumps are the same 2 different pumps of the same hp, can produce vastly different flow rates. Also check that the wires on the front, from breaker and to pump, are tightly secured, and no burn marks. To determine the cause of your noisy pump, investigate the following reasons: Theres no need to feel overwhelmed if your Hayward pool pump isnt functioning correctly. Another piece of information is that the board was replaced back around May of this year as well as the flow sensor. Im having a problem with my super pump. If it humms or buzzes, it could be a bad capacitor, in rear of motor, at 9 oclock. Can u shed any light on what might be the culprit? Use the [7/16] wrench to wiggle the shaft through several revolutionsto free up the shaft. It could be air in the pump, or it could be that the pump is too big (powerful) for the number of pipes. Pool pump already went out a few months ago. my two speed Hayword pump clicks when Hi Jamie, definitely want to use 100 lbs of Pool Filter Sand, unless you are using a sand replacement like Zeosand or FilterGlass. Anyone else have a scientific explanation? I have cleaned the rubber gasket, made sure the springs touch to no avail. No moisture. So it seems its changing speeds from slow to normal or is shutting off and immediately turning back on. One thing I discovered is that if I place it in super chlorinate mode today, once the pool pump shuts down for the day, the next day when it turns back on, it will be back in regular chlorinate mode even if the switch is still in super chlorinate mode. So my Hayward melted the whole left sided plastic shrouds. hi I followed the set up directions on my new sp1580lx pump and it keeps tripping the breaker. I doubt you damaged anything, or have any big issues, should be OK. Hi Shannon, assuming that your pump is single speed (not dual speed or variable speed), it runs at a constant 3450 RPM, and is not possible to run at a lower speed. The pipe from the pump is connected to the valve in the port labeled PUMP and the pipe returning to the pool connects to the port labeled RETURN. Maybe the breaker is loose on the bar, or perhaps insects shorting it. The control panel says that theres a driver error. Replumb your flow switch if it does not meet the distance requirements. Bearings produce a loud squealy sound. Is the wire the correct size wire? Read up on it and seems it happens a lot and the motor drive needs to be replaced. You can assist by removing the back cover and placing a fan behind the motor and try again after a day. But lack of sand should not cause a leaking problem. Interesting however that you say the pump works on backwash, but not on filter? You dont have a saltwater pool do you? Hi, loud screeching sounds like bearings, yes. Second thing could be loose wire connections, on the breaker, on the outlet, or on the cords connecting to the pump/trol, or damaged plug ends. Baal School; Skill Training for Girls Hi Doug, good question that indicates that there is an air leak coming into the pump. Not too bad of a repair, if you want to attempt yourself. Also check that wires are tightly attached, at breaker, timer and pump. Replaced motor and seal on my Hayward Northstar. I am getting a CEL code and the heater will not run. K-1766 Taylor Salt Test Also check the threaded pipe that comes into the pump, #1 most common air leak. Tonight, I tried to manually start the filter and all I hear is a click in the mother board. Hi We just bought a new Hayward Powerflo Matrix pump and filter. If I shut the pump off for a little while and put it back on it repeats the same thing over and over, strong at first for about 5 minutes then weak. Hopefully the GFI then holds. HI Alberto, if a motor is overheating, it normally takes about 15-20 minutes, and then the thermal overload switch, located in the rear of the motor, will trip, shutting off the pump for about 15-20 minutes, until it is cool enough to start again, on its own.